NSN 5925-01-323-0238 of Circuit Breaker - Parts Details
Alternative NSN: 5925013230238 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013230238 |
NCB Code: USA (01) |
Manufacturers: Sensata Technologies Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers R15-2-2.00A-B121EV under NSN 5925-01-323-0238 of Circuit Breaker manufactured by Sensata Technologies Inc.
Federal Supply Class of NSN 5925-01-323-0238 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-323-0238, 5925013230238
-
Part No Manufacturer Item Name QTY RFQ R15-2-2.00A-B121EV Sensata Technologies Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925013230238MRC Criteria Characteristic AAQL BODY STYLE SINGLE POLE TYPE ADAT BODY WIDTH 0.760 INCHES MINIMUM AND 0.780 INCHES MAXIMUM ADAU BODY HEIGHT 1.810 INCHES MINIMUM AND 1.870 INCHES MAXIMUM ADTV CASE MATERIAL PLASTIC AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW AKPX POLE QUANTITY 1 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 CLIP BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC SINGLE LOCATION AND 2.0 AMPERES DC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION AND 65.0 DC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION AND 1000.0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION CQSM SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE ONE CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 1.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 15.000 MAXIMUM AT 200 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 3.0 AC AND 1.5 DC CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 120.0 AC AND 32.0 DC AJEC BOSS HEIGHT 0.083 INCHES MINIMUM AND 0.103 INCHES MAXIMUM ADAQ BODY LENGTH 1.550 INCHES MINIMUM AND 1.570 INCHES MAXIMUM AFJN FRAGILITY FACTOR MODERATELY RUGGED CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE FREQ FREQUENCY IN HERTZ 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION TTQY TERMINAL TYPE AND QUANTITY 2 QUICK DISCONNECT, MALE
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAT | BODY WIDTH | 0.760 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.810 INCHES MINIMUM AND 1.870 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC SINGLE LOCATION AND 2.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION AND 65.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION AND 1000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 1.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 15.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 3.0 AC AND 1.5 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 32.0 DC |
AJEC | BOSS HEIGHT | 0.083 INCHES MINIMUM AND 0.103 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.550 INCHES MINIMUM AND 1.570 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
FREQ | FREQUENCY IN HERTZ | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |