NSN 5925-01-341-6758 of Circuit Breaker - Parts Details
Alternative NSN: 5925013416758 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013416758 |
NCB Code: USA (01) |
Manufacturers: Agustawestland International Lim , Sensata Technologies Inc , Bell Helicopter Textron Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 3TC14-30, 30-014-30 under NSN 5925-01-341-6758 of Circuit Breaker manufactured by Agustawestland International Lim, Sensata Technologies Inc, Bell Helicopter Textron Inc.
Federal Supply Class of NSN 5925-01-341-6758 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-341-6758, 5925013416758
Characteristics Data of NSN 5925013416758MRC Criteria Characteristic CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000 0 AC AND 6000 0 DC SINGLE LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION AAQL BODY STYLE SINGLE POLE TYPE CPRQ RESET METHOD MANUAL TTQY TERMINAL TYPE AND QUANTITY 2 TAB WSCREW ADAQ BODY LENGTH 1 100 INCHES MAXIMUM ADAT BODY WIDTH 0 781 INCHES MAXIMUM AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1 218 INCHES NOMINAL AKPX POLE QUANTITY 1 AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING CMLP THREAD QUANTITY PER INCH 32 CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120 0 AC AND 30 0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE FREQ FREQUENCY IN HERTZ 400 0 SINGLE LOCATION ABXD BUSHING LENGTH 0 250 INCHES NOMINAL AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0 740 INCHES NOMINAL AFJN FRAGILITY FACTOR MODERATELY RUGGED APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE BBRJ SPECIAL HANDLING FEATURE MAGNETIC CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30 0 AMPERES AC AND 30 0 AMPERES DC SINGLE LOCATION CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150 0 SINGLE LOCATION CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH-PULL CQJX NOMINAL THREAD SIZE 0 468 INCHES CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 6 000 MINIMUM AT 200 PCT AND 35 000 MAXIMUM AT 200 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF CWJK CASE MATERIAL PLASTIC THSD THREAD SERIES DESIGNATOR UNS
MRC | Criteria | Characteristic |
---|---|---|
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000 0 AC AND 6000 0 DC SINGLE LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CPRQ | RESET METHOD | MANUAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB WSCREW |
ADAQ | BODY LENGTH | 1 100 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0 781 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1 218 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120 0 AC AND 30 0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
FREQ | FREQUENCY IN HERTZ | 400 0 SINGLE LOCATION |
ABXD | BUSHING LENGTH | 0 250 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0 740 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30 0 AMPERES AC AND 30 0 AMPERES DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150 0 SINGLE LOCATION |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CQJX | NOMINAL THREAD SIZE | 0 468 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6 000 MINIMUM AT 200 PCT AND 35 000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
CWJK | CASE MATERIAL | PLASTIC |
THSD | THREAD SERIES DESIGNATOR | UNS |