NSN 5925-01-394-6057 of Circuit Breaker - Parts Details
Alternative NSN: 5925013946057 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013946057 |
NCB Code: USA (01) |
Manufacturers: Dla Land And Maritime |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 87059-026 under NSN 5925-01-394-6057 of Circuit Breaker manufactured by Dla Land And Maritime.
Federal Supply Class of NSN 5925-01-394-6057 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-394-6057, 5925013946057
Characteristics Data of NSN 5925013946057MRC Criteria Characteristic AKPX Pole Quantity 3 MRC Decoded Requirement Clear Text Reply CPLM Maximum Continuous Load Current Rating Per Pole 5.0 AMPERES AC ALL LOCATIONS AND 5.0 AMPERES DC ALL LOCATIONS ABXD Bushing Length 0.380 INCHES MAXIMUM AJWX Mounting Surface To Terminal End Distance 1.780 INCHES MAXIMUM FREQ Frequency In Hertz 400.0 ALL LOCATIONS CPRF Operating Voltage Type And Rating Per Pole In Volts 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS CPRH Circuit Protection Type OVERCURRENT ALL LOCATIONS CQSM Switch Location And Position Designation INTERNAL AT POLE ONE CPRJ Trip Release Method MAGNETIC SINGLE LOCATION AXHR Mounting Facility Type And Quantity 1 THREADED BUSHING W/PANEL SEAL AEGJ Switch Contact Arrangement SINGLE POLE, DOUBLE THROW CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 125.0 ALL LOCATIONS CPRL Trip Release Characteristic TIME DELAY ALL LOCATIONS CPRR Main Contact Tripping Mechanism Type TRIP FREE CSSX Switch Current Rating And Type In Amps 0.5 AC AND 0.5 DC ADAT Body Width 1.562 INCHES MAXIMUM CPRX Actuator Position Designation AT POLE TWO CPRT Manual Actuator Type And Quantity 1 TOGGLE ADTV Case Material METAL CPSM Internal Trip Release Configuration SERIES TRIP SINGLE LOCATION CPRW Actuator Function TRIP-RESET CSWP Switch Voltage Rating And Type In Volts 120.0 AC AND 50.0 DC CRTK Switch Terminal Type TAB, SOLDER LUG THSD Thread Series Designator UNEF CQJX Nominal Thread Size 0.375 INCHES ADAQ Body Length 1.937 INCHES MAXIMUM AEBP Center To Center Distance Between Terminals Parallel To Length 0.875 INCHES NOMINAL TTQY Terminal Type And Quantity 6 WIRE HOOK AAQL Body Style MULTIPOLE-SINGLE ACTUATOR TYPE AEBQ Center To Center Distance Between Terminals Parallel To Width 0.625 INCHES NOMINAL CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 300.0 AC SINGLE LOCATION AND 500.0 DC SINGLE LOCATION CQWN Trip Delay Time In Seconds Per Rated Continuous Current 0.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS CPRQ Reset Method MANUAL CPRZ Auxiliary Switch Function And Quantity 1 ALARM
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS AND 5.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CSSX | Switch Current Rating And Type In Amps | 0.5 AC AND 0.5 DC |
ADAT | Body Width | 1.562 INCHES MAXIMUM |
CPRX | Actuator Position Designation | AT POLE TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRW | Actuator Function | TRIP-RESET |
CSWP | Switch Voltage Rating And Type In Volts | 120.0 AC AND 50.0 DC |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
THSD | Thread Series Designator | UNEF |
CQJX | Nominal Thread Size | 0.375 INCHES |
ADAQ | Body Length | 1.937 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 6 WIRE HOOK |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC SINGLE LOCATION AND 500.0 DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |