NSN 5930-00-969-2713 of Switch Thermostatic - Parts Details
Alternative NSN: 5930009692713 |
Item Name: Switch Thermostatic |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 009692713 |
NCB Code: USA (00) |
Manufacturers: Bauer Inc , United Electric Controls Company |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers E5-70B1BR441, E5-70B1, E5-70B-1, 079PC4, 079PC3 under NSN 5930-00-969-2713 of Switch Thermostatic manufactured by Bauer Inc, United Electric Controls Company.
Federal Supply Class of NSN 5930-00-969-2713 is FSC 5930 contains part details of Switches. Quote for your desired part numbers.
Part Number's List for NSN 5930-00-969-2713, 5930009692713
-
Part No Manufacturer Item Name QTY RFQ E5-70B1BR441 Bauer Inc switch thermostatic Avl RFQ E5-70B1BR441 United Electric Controls Company switch thermostatic Avl RFQ E5-70B1 United Electric Controls Company switch thermostatic Avl RFQ E5-70B-1 Bauer Inc switch thermostatic Avl RFQ 079PC4 Bauer Inc switch thermostatic Avl RFQ 079PC3 Bauer Inc switch thermostatic Avl RFQ
Characteristics Data of NSN 5930009692713MRC Criteria Characteristic ABKW OVERALL HEIGHT 7.749 INCHES NOMINAL ABMK OVERALL WIDTH 1.562 INCHES NOMINAL ADAQ BODY LENGTH 4.250 INCHES NOMINAL AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.190 INCHES NOMINAL AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 4.250 INCHES NOMINAL AEVT CAPILLARY TUBE LENGTH 72.0 INCHES NOMINAL AEVU BULB LENGTH 4.219 INCHES NOMINAL AEVV BULB DIAMETER 0.375 INCHES NOMINAL AKBY TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB AXGY MOUNTING METHOD BRACKET AND UNTHREADED HOLE CBBL FEATURES PROVIDED ELECTRICAL ACCESS PORT CQGB CONTACT ACTION STIMULUS INCREASE CQYJ MOUNTING FACILITY PATTERN TWO POSITION IN-LINE CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY CSCF TERMINAL TYPE SCREW CTHF CONTACT LOAD CURRENT RATING 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE CTYC CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE CTYM CONTACT ADJUSTMENT RANGE +0.00/+100.00 ACTUATION POINT DEGREES FAHRENHEIT AND +0.00/+100.00 DEACTUATION POINT DEGREES FAHRENHEIT CTYS CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB CTZB CONTACT VOLTAGE RATING IN VOLTS 250.0 AC AT SEA LEVEL SINGLE VOLTAGE MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID STYL III STYLE DESIGNATOR RECTANGULAR
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 7.749 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.562 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.250 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 72.0 INCHES NOMINAL |
AEVU | BULB LENGTH | 4.219 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00/+100.00 ACTUATION POINT DEGREES FAHRENHEIT AND +0.00/+100.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | III STYLE DESIGNATOR | RECTANGULAR |