NSN 5945-00-435-6624 of Relay Electromagnetic - Parts Details
Alternative NSN: 5945004356624 |
Item Name: Relay Electromagnetic |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 004356624 |
NCB Code: USA (00) |
Manufacturers: Pickard And Burns Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 06-12481-1 under NSN 5945-00-435-6624 of Relay Electromagnetic manufactured by Pickard And Burns Inc.
Federal Supply Class of NSN 5945-00-435-6624 is FSC 5945 contains part details of Relays and Solenoids. Quote for your desired part numbers.
Part Number's List for NSN 5945-00-435-6624, 5945004356624
-
Part No Manufacturer Item Name QTY RFQ 06-12481-1 Pickard And Burns Inc relay electromagnetic Avl RFQ
Characteristics Data of NSN 5945004356624MRC Criteria Characteristic ABHP OVERALL LENGTH 1.180 INCHES NOMINAL ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.200 INCHES NOMINAL SINGLE MOUNTING FACILITY ABKW OVERALL HEIGHT 0.380 INCHES NOMINAL ABMK OVERALL WIDTH 1.010 INCHES NOMINAL ADZC ENVIRONMENTAL PROTECTION HERMETIC AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY AKDX WINDING QUANTITY 1 APCN COIL QUANTITY 1 APNA WINDING DC RESISTANCE RATING 500.0 OHMS NOMINAL SINGLE WINDING APNP DUTY TYPE CONTINUOUS AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.180 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.200 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.380 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.010 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |