FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 001037700 |
NCB Code: USA (00) |
Manufacturers: Mccarron Electric Co , Honeywell International Inc , Robert M Hadley Company Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers M-3159, 805358-1, 16289 under NSN 5950-00-103-7700 of Transformer Power manufactured by Mccarron Electric Co, Honeywell International Inc, Robert M Hadley Company Inc.
Federal Supply Class of NSN 5950-00-103-7700 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-103-7700, 5950001037700
Characteristics Data of NSN 5950001037700MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKW OVERALL HEIGHT 2.687 INCHES MAXIMUM ACZB FREQUENCY RATING 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ACZF MAXIMUM TRANSFORMER POWER RATING 35.0 VOLT-AMPERE SINGLE COMPONENT ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT ADAQ BODY LENGTH 1.320 INCHES MAXIMUM ADAT BODY WIDTH 1.320 INCHES MAXIMUM ADAU BODY HEIGHT 2.250 INCHES MAXIMUM AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.265 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AKNA INCLOSURE TYPE HERMETICALLY SEALED AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP CRBZ WINDING OPERATING CURRENT 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY CRBZ WINDING OPERATING CURRENT 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY CRBZ WINDING OPERATING CURRENT 170.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY CRBZ WINDING OPERATING CURRENT 25.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY CWJS WINDING OPERATING VOLTAGE 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY CWJS WINDING OPERATING VOLTAGE 35.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY CWJS WINDING OPERATING VOLTAGE 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY CWJS WINDING OPERATING VOLTAGE 5.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP TTQY TERMINAL TYPE AND QUANTITY 14 WIRE HOOK
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKW | OVERALL HEIGHT | 2.687 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 35.0 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.320 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.320 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.250 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.265 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 170.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 35.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK |