NSN 5950-00-903-8067 of Transformer Power - Parts Details
Alternative NSN: 5950009038067 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 009038067 |
NCB Code: USA (00) |
Manufacturers: Microtran Co Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers M7410 under NSN 5950-00-903-8067 of Transformer Power manufactured by Microtran Co Inc.
Federal Supply Class of NSN 5950-00-903-8067 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-903-8067, 5950009038067
Characteristics Data of NSN 5950009038067MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ACZB FREQUENCY RATING 4.8 KILOHERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ADAQ BODY LENGTH 1.125 INCHES NOMINAL ADAT BODY WIDTH 1.125 INCHES NOMINAL ADAU BODY HEIGHT 1.219 INCHES NOMINAL AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.234 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AKNA INCLOSURE TYPE HERMETICALLY SEALED AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP CRBZ WINDING OPERATING CURRENT 75.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY CRBZ WINDING OPERATING CURRENT 785.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY CWJS WINDING OPERATING VOLTAGE 25.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 25.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY CWJS WINDING OPERATING VOLTAGE 3.40 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP TTQY TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 4.8 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.125 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.125 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.219 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.234 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 75.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 785.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 3.40 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |