NSN 5950-00-946-8131 of Transformer Power - Parts Details
Alternative NSN: 5950009468131 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 009468131 |
NCB Code: USA (00) |
Manufacturers: Transformer Engineering Llc , Raytheon Aircraft , Magnetek Inc , Altec Lansing Corp |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers TE11541, 874107, 722803-29, 722803-029, 71091 under NSN 5950-00-946-8131 of Transformer Power manufactured by Transformer Engineering Llc, Raytheon Aircraft, Magnetek Inc, Altec Lansing Corp.
Federal Supply Class of NSN 5950-00-946-8131 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-946-8131, 5950009468131
-
Part No Manufacturer Item Name QTY RFQ TE11541 Transformer Engineering Llc transformer power Avl RFQ 874107 Raytheon Aircraft transformer power Avl RFQ 722803-29 Raytheon Aircraft transformer power Avl RFQ 722803-029 Raytheon Aircraft transformer power Avl RFQ 71091 Magnetek Inc transformer power Avl RFQ 7053 Altec Lansing Corp transformer power Avl RFQ
Characteristics Data of NSN 5950009468131MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ACZB FREQUENCY RATING 47.5 HERTZ MINIMUM SINGLE COMPONENT AND 460.0 HERTZ MAXIMUM SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT ACZD TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT ADAQ BODY LENGTH 5.750 INCHES MAXIMUM ADAT BODY WIDTH 4.000 INCHES MAXIMUM ADAU BODY HEIGHT 8.500 INCHES MAXIMUM AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT CMLP THREAD QUANTITY PER INCH 20 SINGLE GROUP CQJX NOMINAL THREAD SIZE 0.250 INCHES SINGLE GROUP CRBZ WINDING OPERATING CURRENT 11.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY CWJS WINDING OPERATING VOLTAGE 20.80 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP TTQY TERMINAL TYPE AND QUANTITY 17 THREADED STUD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 47.5 HERTZ MINIMUM SINGLE COMPONENT AND 460.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 8.500 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 11.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.80 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 17 THREADED STUD |