NSN 6130-01-033-3077 of Power Supply - Parts Details
Alternative NSN: 6130010333077 |
Item Name: Power Supply |
FSG: 61 Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC): 6130 Converters Electrical Non Rotating |
NIIN: 010333077 |
NCB Code: USA (01) |
Manufacturers: American Telephone And Telegraph , Telemechanics Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 40PSU103 under NSN 6130-01-033-3077 of Power Supply manufactured by American Telephone And Telegraph, Telemechanics Inc.
Federal Supply Class of NSN 6130-01-033-3077 is FSC 6130 contains part details of Converters Electrical Non Rotating. Quote for your desired part numbers.
Part Number's List for NSN 6130-01-033-3077, 6130010333077
Characteristics Data of NSN 6130010333077MRC Criteria Characteristic AGAV END ITEM IDENTIFICATION TELETYPE MODEL 40 KDP SET APNX INPUT VOLTAGE RATING 103.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 127.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT APPA OUTPUT VOLTAGE RATING -11.58 DC VOLTS MINIMUM 3RD POWER OUTPUT AND -12.42 DC VOLTS MAXIMUM 3RD POWER OUTPUT APPA OUTPUT VOLTAGE RATING 11.58 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 12.42 DC VOLTS MAXIMUM 2ND POWER OUTPUT APPA OUTPUT VOLTAGE RATING 4.9 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 5.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT APTQ INPUT FREQUENCY RATING 49.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT AYNH OPERATING AMBIENT TEMP RANGE +0.1/+45.0 DEG CELSIUS CWGH OUTPUT CURRENT RATING 0.4 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT CWGH OUTPUT CURRENT RATING 0.4 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT CWGH OUTPUT CURRENT RATING 5.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 25.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY TEMPEST MODEL 40 POWER SUPPLY FEAT SPECIAL FEATURES POWER SUPPLY FURNISHES THESE REGULATED VOLTAGES AND CURRENTS FOR THE 40C400 CONTROLLER LOGIC
MRC | Criteria | Characteristic |
---|---|---|
AGAV | END ITEM IDENTIFICATION | TELETYPE MODEL 40 KDP SET |
APNX | INPUT VOLTAGE RATING | 103.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 127.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -11.58 DC VOLTS MINIMUM 3RD POWER OUTPUT AND -12.42 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 11.58 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 12.42 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 4.9 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 5.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 49.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+45.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 0.4 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.4 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 5.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 25.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | TEMPEST MODEL 40 POWER SUPPLY |
FEAT | SPECIAL FEATURES | POWER SUPPLY FURNISHES THESE REGULATED VOLTAGES AND CURRENTS FOR THE 40C400 CONTROLLER LOGIC |