20-000303-002 by Bae Systems Information And Electronic Systems Integration Inc Div Bae Systems with NSN 5950010670996 - Submit a Quote
Part No. : 20-000303-002 | Alternate P/N: 20000303002 | Manufacturer : Bae Systems Information And Electronic Systems Integration Inc Div Bae Systems | NSN : 5950-01-067-0996 |
Item Name : Transformer Power | CAGE Code : 12436 | FSC : 5950 Coils and Transformers |
ASAP Aviation Procurement is pleased to announce that part number 20-000303-002 of NSN 5950010670996 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number 20-000303-002 is a transformer power manufactured by bae systems information and electronic systems integration inc div bae systems under CAGE Code 12436. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. 20-000303-002 bae systems information and electronic systems integration inc div bae systems is in stock.
Are you interested in learning more about part number 20-000303-002? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number 20-000303-002 with NSN 5950-01-067-0996, 5950010670996
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-067-0996 Item Description: Transformer Power | 5950 | 010670996 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
20-000303-002 | 6 | 1 | C | A |
Characteristics Data of NSN 5950-01-067-0996, 5950010670996MRC Criteria Characteristic POWER AARG RELIABILITY INDICATORNOT ESTABLISHED POWER ABFE HAZARDOUS LOCATIONSENVIRONMENTAL PROTECTIONMOISTURE RESISTANT AND VIBRATION RESISTANT POWER ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1 688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP POWER ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1 438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP POWER ACZB FREQUENCY RATING60 0 HERTZ NOMINAL SINGLE COMPONENT POWER ACZC INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT POWER ACZX WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT POWER ADAQ BODY LENGTH2 187 INCHES MINIMUM AND 2 312 INCHES MAXIMUM POWER ADAT BODY WIDTH1 874 INCHES MINIMUM AND 2 062 INCHES MAXIMUM POWER ADAU BODY HEIGHT2 937 INCHES MINIMUM AND 3 125 INCHES MAXIMUM POWER AEHZ MAXIMUM OPERATING TEMP130 0 DEG CELSIUS POWER AKNA INCLOSURE TYPEHERMETICALLY SEALED POWER AKPV MOUNTING FACILITY QUANTITY4 SINGLE GROUP POWER AXGY MOUNTING METHODTHREADED STUD SINGLE GROUP POWER BPLC WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT POWER CQJX NOMINAL THREAD SIZE0 138 INCHES SINGLE GROUP POWER CRBZ WINDING OPERATING CURRENT400 0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT ALL SECONDARY POWER CWJS WINDING OPERATING VOLTAGE115 00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY POWER FEAT SPECIAL FEATURESTERMINALS 1 AND 4 ARE SPLIT TO MAKE TERMINALS 2 AND 3 ON THE PRIMARY WINDING POWER TEST TEST DATA DOCUMENT06809-20-000303 DRAWING THIS IS THE BASIC GOVERNING DRAWING SUCH AS A CONTRACTOR DRAWING ORIGINAL EQUIPMENT MANUFACTURER DRAWING ETC EXCLUDES ANY SPECIFICATION STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR POWER THSD THREAD SERIES DESIGNATORUNC SINGLE GROUP POWER TTQY TERMINAL TYPE AND QUANTITY10 TURRET
MRC | Criteria | Characteristic |
---|---|---|
POWER | AARG | RELIABILITY INDICATORNOT ESTABLISHED |
POWER | ABFE | HAZARDOUS LOCATIONSENVIRONMENTAL PROTECTIONMOISTURE RESISTANT AND VIBRATION RESISTANT |
POWER | ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1 688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1 438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ACZB | FREQUENCY RATING60 0 HERTZ NOMINAL SINGLE COMPONENT |
POWER | ACZC | INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
POWER | ACZX | WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
POWER | ADAQ | BODY LENGTH2 187 INCHES MINIMUM AND 2 312 INCHES MAXIMUM |
POWER | ADAT | BODY WIDTH1 874 INCHES MINIMUM AND 2 062 INCHES MAXIMUM |
POWER | ADAU | BODY HEIGHT2 937 INCHES MINIMUM AND 3 125 INCHES MAXIMUM |
POWER | AEHZ | MAXIMUM OPERATING TEMP130 0 DEG CELSIUS |
POWER | AKNA | INCLOSURE TYPEHERMETICALLY SEALED |
POWER | AKPV | MOUNTING FACILITY QUANTITY4 SINGLE GROUP |
POWER | AXGY | MOUNTING METHODTHREADED STUD SINGLE GROUP |
POWER | BPLC | WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
POWER | CQJX | NOMINAL THREAD SIZE0 138 INCHES SINGLE GROUP |
POWER | CRBZ | WINDING OPERATING CURRENT400 0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
POWER | CWJS | WINDING OPERATING VOLTAGE115 00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
POWER | FEAT | SPECIAL FEATURESTERMINALS 1 AND 4 ARE SPLIT TO MAKE TERMINALS 2 AND 3 ON THE PRIMARY WINDING |
POWER | TEST | TEST DATA DOCUMENT06809-20-000303 DRAWING THIS IS THE BASIC GOVERNING DRAWING SUCH AS A CONTRACTOR DRAWING ORIGINAL EQUIPMENT MANUFACTURER DRAWING ETC EXCLUDES ANY SPECIFICATION STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |
POWER | THSD | THREAD SERIES DESIGNATORUNC SINGLE GROUP |
POWER | TTQY | TERMINAL TYPE AND QUANTITY10 TURRET |
Related NSN Components For 20-000303-002
Part 20-000303-002 With Different Manufacturers
Industry's fastest RFQ turnaround. Get the answers you need now.
E-mail us at
sales@asap-aviationprocurement.com