CD5-Z14-1 by Eaton Corp with NSN 5925013308678 - Submit a Quote
Part No. : CD5-Z14-1 | Alternate P/N: CD5Z141 | Manufacturer : Eaton Corp | NSN : 5925-01-330-8678 |
Item Name : Circuit Breaker | CAGE Code : 74193 | FSC : 5925 Circuit Breakers |
ASAP Aviation Procurement is pleased to announce that part number CD5-Z14-1 of NSN 5925013308678 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number CD5-Z14-1 is a circuit breaker manufactured by eaton corp under CAGE Code 74193. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. CD5-Z14-1 eaton corp is in stock.
Are you interested in learning more about part number CD5-Z14-1? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number CD5-Z14-1 with NSN 5925-01-330-8678, 5925013308678
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-330-8678 Item Description: Circuit Breaker | 5925 | 013308678 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cd5-Z14-1 | 5 | 9 | 5 |
Characteristics Data of NSN 5925-01-330-8678, 5925013308678MRC Criteria Characteristic AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE ABTD MOUNTING SLOT WIDTH 0.164 INCHES NOMINAL ADAQ BODY LENGTH 4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM ADAT BODY WIDTH 5.180 INCHES MAXIMUM ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 3.537 INCHES MINIMUM AND 3.557 INCHES MAXIMUM AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM AFJN FRAGILITY FACTOR MODERATELY RUGGED AJEC BOSS HEIGHT 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 3.475 INCHES MINIMUM AND 3.495 INCHES MAXIMUM APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 10 THREADED HOLE AND 5 SLOT BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES AC FIRST LOCATION CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES AC SECOND LOCATION CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES AC THIRD LOCATION CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES DC FIFTH LOCATION CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES DC FOURTH LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 140.0 DC FOURTH LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC FIRST LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC THIRD LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC THIRD LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 DC FOURTH LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FIFTH LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FOURTH LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES/RELAY TRIP FIRST LOCATION CQQC TRIP RELEASE DUTY CYCLE CONTINUOUS FIRST LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 20.000 MINIMUM AT 200 PCT THIRD LOCATION AND 100.000 MAXIMUM AT 200 PCT THIRD LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 25.000 MINIMUM AT 200 PCT FIFTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FIFTH LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 25.000 MINIMUM AT 200 PCT FOURTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FOURTH LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF FREQ FREQUENCY IN HERTZ 60.0 FIRST LOCATION FREQ FREQUENCY IN HERTZ 60.0 SECOND LOCATION FREQ FREQUENCY IN HERTZ 60.0 THIRD LOCATION TTQY TERMINAL TYPE AND QUANTITY 12 THREADED STUD CMLP THREAD QUANTITY PER INCH 32 CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC SECOND LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 DC FIFTH LOCATION CPRK AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS 25.0 DC NOMINAL FIRST LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 140.0 DC FIFTH LOCATION CPRW ACTUATOR FUNCTION TRIP-RESET CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SECOND LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP THIRD LOCATION CQJX NOMINAL THREAD SIZE 0.138 INCHES CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 20.000 MINIMUM AT 200 PCT FIRST LOCATION AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION THSD THREAD SERIES DESIGNATOR UNC AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM AKPX POLE QUANTITY 5 CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC FIRST LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SECOND LOCATION CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS CPRT MANUAL ACTUATOR TYPE AND QUANTITY 5 TOGGLE CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, THREE, FOUR, AND FIVE LINKED CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 20.000 MINIMUM AT 200 PCT SECOND LOCATION AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION FEAT SPECIAL FEATURES FULL LENGTH BARRIERS BETWEEN POLES INCLUDED
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABTD | MOUNTING SLOT WIDTH | 0.164 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM |
ADAT | BODY WIDTH | 5.180 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.537 INCHES MINIMUM AND 3.557 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.475 INCHES MINIMUM AND 3.495 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 10 THREADED HOLE AND 5 SLOT |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC SECOND LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC THIRD LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC FIFTH LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC FOURTH LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 140.0 DC FOURTH LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC THIRD LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC THIRD LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 DC FOURTH LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIFTH LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FOURTH LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES/RELAY TRIP FIRST LOCATION |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS FIRST LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT THIRD LOCATION AND 100.000 MAXIMUM AT 200 PCT THIRD LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 25.000 MINIMUM AT 200 PCT FIFTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FIFTH LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 25.000 MINIMUM AT 200 PCT FOURTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FOURTH LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 THIRD LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 DC FIFTH LOCATION |
CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 25.0 DC NOMINAL FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 140.0 DC FIFTH LOCATION |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT FIRST LOCATION AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 5 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 5 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, FOUR, AND FIVE LINKED |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT SECOND LOCATION AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION |
FEAT | SPECIAL FEATURES | FULL LENGTH BARRIERS BETWEEN POLES INCLUDED |
Related NSN Components For CD5-Z14-1
Industry's fastest RFQ turnaround. Get the answers you need now.
E-mail us at
sales@asap-aviationprocurement.com