43656 by Freed Transformer Company with NSN 5950004105141 - Submit a Quote
Part No. : 43656 | Manufacturer : Freed Transformer Company | NSN : 5950-00-410-5141 |
Item Name : Transformer Power | CAGE Code : 73386 | FSC : 5950 Coils and Transformers |
ASAP Aviation Procurement is pleased to announce that part number 43656 of NSN 5950004105141 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number 43656 is a transformer power manufactured by freed transformer company under CAGE Code 73386. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. 43656 freed transformer company is in stock.
Are you interested in learning more about part number 43656? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number 43656 with NSN 5950-00-410-5141, 5950004105141
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-410-5141 Item Description: Transformer Power | 5950 | 004105141 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
43656 | 6 | 2 | 5 |
Characteristics Data of NSN 5950-00-410-5141, 5950004105141MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHEDNOT ESTABLISHED ABHP OVERALL LENGTH 3.500 INCHES MAXIMUM3.500 INCHES MAXIMUM ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.960 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.960 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKW OVERALL HEIGHT 2.300 INCHES MAXIMUM2.300 INCHES MAXIMUM ABMK OVERALL WIDTH 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO TWO PHASE SINGLE COMPONENTTHREE PHASE TO TWO PHASE SINGLE COMPONENT ACZD TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA AND WYE-DELTA AND WYE-OPEN DELTAWYE-OPEN DELTA ACZF MAXIMUM TRANSFORMER POWER RATING 330.1 VOLT-AMPERE SINGLE COMPONENT330.1 VOLT-AMPERE SINGLE COMPONENT ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS130.0 DEG CELSIUS AKNA INCLOSURE TYPE FULLY INCLOSEDFULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP4 SINGLE GROUP AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP BFMF COOLING METHOD SELF-COOLEDSELF-COOLED BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP0.138 INCHES SINGLE GROUP CRBZ WINDING OPERATING CURRENT 2.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY CRBZ WINDING OPERATING CURRENT 2.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY CRBZ WINDING OPERATING CURRENT 3.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY CRBZ WINDING OPERATING CURRENT 800.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY CRMJ WINDING POWER RATING 134.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY CRMJ WINDING POWER RATING 134.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY90.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY90.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY CRMJ WINDING POWER RATING 90.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY10.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY90.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY CRMJ WINDING POWER RATING 90.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY134.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY CWJS WINDING OPERATING VOLTAGE 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY7.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY CWJS WINDING OPERATING VOLTAGE 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY7.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY FEAT SPECIAL FEATURES ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP TTQY TERMINAL TYPE AND QUANTITY 18 TAB, SOLDER LUG
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.500 INCHES MAXIMUM3.500 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.960 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.960 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 2.300 INCHES MAXIMUM2.300 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO TWO PHASE SINGLE COMPONENTTHREE PHASE TO TWO PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA AND WYE-DELTA AND WYE-OPEN DELTAWYE-OPEN DELTA |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 330.1 VOLT-AMPERE SINGLE COMPONENT330.1 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BFMF | COOLING METHOD | SELF-COOLEDSELF-COOLED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 134.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 134.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY90.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY90.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 90.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY10.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY90.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 90.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY134.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY7.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY7.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 18 TAB, SOLDER LUG |
Related NSN Components For 43656
Part 43656 With Different Manufacturers
Industry's fastest RFQ turnaround. Get the answers you need now.
E-mail us at
sales@asap-aviationprocurement.com