ASAP Aviation Procurement is pleased to announce that part number KDL-D2A-006 of NSN 5945-01-332-8005 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number KDL-D2A-006 is a Relay Electromagnetic manufactured by Leach International Corporation under CAGE Code 58657. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote. In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. KDL-D2A-006 Leach International Corporation is in stock.
Are you interested in learning more about part number KDL-D2A-006? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-332-8005 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013328005 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
KDL-D2A-006 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.615 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.635 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC MOTOR LOAD AND 10.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE HOOK ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.718 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.655 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.025 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.140 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
APCN | COIL QUANTITY | 1 |
CBME | CUBIC MEASURE | 2.914 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 75.0 MILLIAMPERES DC SINGLE WINDING |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES AC INDUCTIVE LOAD AND 12.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC INDUCTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD |
AGAV | END ITEM IDENTIFICATION | WEAPONS DELIV |
APNQ | ARC QUENCHING METHOD | AIR |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CRXH | TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNA | WINDING DC RESISTANCE RATING | 450.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC LAMP LOAD |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Before You Go, Take a look To Our Extensive Range of NSN Parts Catalog. We Provide High Quality NSN Parts with 24/7 Quotation Facility.
Request for Quote