M-4163-1 by Mccarron Electric Co with NSN 5950011859836 - Submit a Quote
Part No. : M-4163-1 | Alternate P/N: M41631 | Manufacturer : Mccarron Electric Co | NSN : 5950-01-185-9836 |
Item Name : Transformer Power | CAGE Code : 08068 | FSC : 5950 Coils and Transformers |
ASAP Aviation Procurement is pleased to announce that part number M-4163-1 of NSN 5950011859836 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number M-4163-1 is a transformer power manufactured by mccarron electric co under CAGE Code 08068. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. M-4163-1 mccarron electric co is in stock.
Are you interested in learning more about part number M-4163-1? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number M-4163-1 with NSN 5950-01-185-9836, 5950011859836
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-185-9836 Item Description: Transformer Power | 5950 | 011859836 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M-4163-1 | 5 | 2 | 3 |
Characteristics Data of NSN 5950-01-185-9836, 5950011859836MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABTD MOUNTING SLOT WIDTH 0.200 INCHES NOMINAL SINGLE GROUP ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ACZX WINDING SHIELDING METHOD INTERNALLY SHIELDED SINGLE COMPONENT ADAQ BODY LENGTH 3.188 INCHES MAXIMUM ADAT BODY WIDTH 3.125 INCHES MAXIMUM ADAU BODY HEIGHT 3.812 INCHES MAXIMUM AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD SLOT SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT CRBZ WINDING OPERATING CURRENT 2.5 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY CWJS WINDING OPERATING VOLTAGE 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY CWJS WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY CWJS WINDING OPERATING VOLTAGE 27.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY TTQY TERMINAL TYPE AND QUANTITY 10 WIRE LEAD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.200 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.188 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.125 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.812 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 27.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |