ASAP Aviation Procurement is pleased to announce that part number IULHK1119-30372-20 of NSN 5925-01-501-6074 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number IULHK1119-30372-20 is a Circuit Breaker manufactured by Sensata Technologies Inc under CAGE Code 81541. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote. In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. IULHK1119-30372-20 Sensata Technologies Inc is in stock.
Are you interested in learning more about part number IULHK1119-30372-20? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-501-6074 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015016074 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
IULHK1119-30372-20 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.250 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC THIRD LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 120.0 MILLIAMPERES DC FOURTH LOCATION |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 70.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AJEC | Boss Height | 1.042 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED STUD |
ADAT | Body Width | 2.490 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
AGAV | End Item Identification | 5895-01-467-7213 |
ADTV | Case Material | METAL |
AJWX | Mounting Surface To Terminal End Distance | 2.529 INCHES NOMINAL |
ADAQ | Body Length | 3.015 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT FIRST LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT THIRD LOCATION |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.000 NOMINAL AT 125 PCT FOURTH LOCATION |
![]() |