311-1273-00 by Tektronix Inc with NSN 5905004306271 - Submit a Quote
Part No. : 311-1273-00 | Alternate P/N: 311127300 | Manufacturer : Tektronix Inc | NSN : 5905-00-430-6271 |
Item Name : Resistor Variable Nonwire Wound | CAGE Code : 80009 | FSC : 5905 Resistors |
ASAP Aviation Procurement is pleased to announce that part number 311-1273-00 of NSN 5905004306271 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number 311-1273-00 is a resistor variable nonwire wound manufactured by tektronix inc under CAGE Code 80009. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. 311-1273-00 tektronix inc is in stock.
Are you interested in learning more about part number 311-1273-00? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number 311-1273-00 with NSN 5905-00-430-6271, 5905004306271
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-430-6271 Item Description: Resistor Variable Nonwire Wound | 5905 | 004306271 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
311-1273-00 | 2 | 2 | 3 |
Characteristics Data of NSN 5905-00-430-6271, 5905004306271MRC Criteria Characteristic AAPN SECTION QUANTITY 1 AAQL BODY STYLE CYLINDRICAL AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHP III OVERALL LENGTH 0.469 INCHES MAXIMUM ABJT TERMINAL LENGTH 0.188 INCHES MINIMUM ABPM BODY DIAMETER 0.266 INCHES MAXIMUM ADAQ BODY LENGTH 0.281 INCHES MAXIMUM ADAV III OVERALL DIAMETER 0.266 INCHES MAXIMUM AEFD ACTUATOR TYPE FLUSH DRIVE WITH SLOT-HOLE AEHT CENTER TO CENTER DISTANCE BETWEEN TERMINALS 0.220 INCHES MAXIMUM APXH TERMINAL LOCATION RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE AXGY MOUNTING METHOD TERMINAL CQCC ELECTRICAL RESISTANCE PER SECTION 200.0 KILOHMS SINGLE SECTION CQCM CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL 0.110 INCHES MAXIMUM CQGN AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER 125.0 SINGLE SECTION CRFJ TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS -100.0 TO 100.0 SINGLE SECTION CRGD POWER DISSIPATION RATING PER SECTION IN WATTS 0.5 FREE AIR SINGLE SECTION CRSS RESISTANCE TOLERANCE PER SECTION IN PERCENT -10.0 TO 10.0 SINGLE SECTION CSDH AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER 85.0 SINGLE SECTION TTQY TERMINAL TYPE AND QUANTITY 3 PIN
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.469 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.188 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.266 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.281 INCHES MAXIMUM |
ADAV | III OVERALL DIAMETER | 0.266 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.220 INCHES MAXIMUM |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 200.0 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.110 INCHES MAXIMUM |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
Related NSN Components For 311-1273-00
Industry's fastest RFQ turnaround. Get the answers you need now.
E-mail us at
sales@asap-aviationprocurement.com