DRY-071219-0008 by Waffensystemkommando Der Luftwaffe with NSN 5945011004479 - Submit a Quote
Part No. : DRY-071219-0008 | Alternate P/N: DRY0712190008 | Manufacturer : Waffensystemkommando Der Luftwaffe | NSN : 5945-01-100-4479 |
Item Name : Relay Electromagnetic | CAGE Code : D9460 | FSC : 5945 Relays and Solenoids |
ASAP Aviation Procurement is pleased to announce that part number DRY-071219-0008 of NSN 5945011004479 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number DRY-071219-0008 is a relay electromagnetic manufactured by waffensystemkommando der luftwaffe under CAGE Code D9460. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. DRY-071219-0008 waffensystemkommando der luftwaffe is in stock.
Are you interested in learning more about part number DRY-071219-0008? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number DRY-071219-0008 with NSN 5945-01-100-4479, 5945011004479
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-100-4479 Item Description: Relay Electromagnetic | 5945 | 011004479 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Dry-071219-0008 | 3 | 9 | 5 |
Characteristics Data of NSN 5945-01-100-4479, 5945011004479MRC Criteria Characteristic ABHP OVERALL LENGTH 1.718 INCHES MAXIMUM ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY ABKW OVERALL HEIGHT 1.635 INCHES NOMINAL ABMK OVERALL WIDTH 1.025 INCHES MAXIMUM ABTD MOUNTING SLOT WIDTH 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY ADZC ENVIRONMENTAL PROTECTION HERMETIC AKDX WINDING QUANTITY 1 APCN COIL QUANTITY 1 APNA WINDING DC RESISTANCE RATING 290.0 OHMS NOMINAL SINGLE WINDING APNP DUTY TYPE CONTINUOUS AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 SLOTTED HOLE SINGLE MOUNTING FACILITY CQYJ MOUNTING FACILITY PATTERN TRIANGLE SINGLE MOUNTING FACILITY CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY CRXH TIME DELAY 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME CSQJ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC MOTOR LOAD AND 10.0 AMPERES DC MOTOR LOAD CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC TEST TEST DATA DOCUMENT 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTIN TTQY TERMINAL TYPE AND QUANTITY 11 TAB, SOLDER LUG ALL FUNCTIONS ZZZK SPECIFICATION/STANDARD DATA 96906-MS27743 GOVERNMENT STANDARD
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.718 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.635 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.025 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 290.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC MOTOR LOAD AND 10.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTIN |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB, SOLDER LUG ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS27743 GOVERNMENT STANDARD |